Century City · fault guide
Chiller running but the building is warm in Century City
A chiller that runs without cooling the building is often not a chiller fault at all. Flow, valves and controls are the usual suspects.
Tenants report warm floors while the plant appears to run. The controller may show no alarm, or only a low differential temperature.
Because the symptom is distributed, the first useful measurement is at the air-handling units and the chilled water loop, not at the chiller.
What usually causes it
Chilled water flow problem
A failed pump, a stuck valve or air in the system stops cold water reaching the coils.
Control not calling for cooling
Sensors, schedules or BMS overrides can leave the plant running without serving the building.
Fouled condenser reducing capacity
High head pressure cuts the machine's output exactly when demand peaks.
Air-side restriction
Blocked filters and dirty coils in the air-handling units make a healthy chiller look inadequate.
Local conditions
How this shows up in Century City
Inland of the beachfront but still marine. Salt is lower than on the coast, yet basement plant rooms and roof enclosures reach high ambient temperatures, canal-side humidity is constant, and kitchen heat loads are far higher than the building's design assumptions.
- Condensers in basement or enclosed service areas recirculating their own hot air
- Body corporate approval needed before any outdoor unit position changes
- Restaurant grease coating condensers and cutting ice machine output
- Office HVAC with poor zoning, so a single floor runs the whole system
- Tenant and landlord equipment responsibility disputes when something fails
Checks you can do safely
- Compare chilled water flow and return temperatures at the plant.
- Check whether air-handling units are running and filters are clean.
- Look for alarms or overrides in the BMS history.
If the loop temperatures look wrong or the plant is tripping, book a diagnostic visit. Chiller work should be measured, not guessed.
Questions we are asked
Where this work sits
Chillers in Century CityNext step
Chiller running but the building is warm in Century City
Send the details and we will come back with the next step. For anything urgent, call or WhatsApp and describe the fault: we will tell you what to do before we arrive.
What helps: the make of the equipment, what it is doing (or not doing), how long it has been like that, and whether the property is occupied.
Where we work: Milnerton, Century City & Royal Ascot. We do not cover suburbs assigned to other Reyds teams, so the local detail on this site stays accurate.
Milnerton source tag applied to every enquiry
Direct contact
Prefer to speak now?
Monday to Friday, 07:30 to 17:00, and Saturday mornings by arrangement. Emergency refrigeration work is taken by phone and attended as soon as the schedule allows.