Fault guide · Air Conditioning

Air conditioning running but not cooling

The unit is on, air is moving, and the room never gets there. Most of these calls are airflow, capacity or siting rather than a loss of gas.

A system that runs all day without reaching set point is working far harder than it should. The first distinction to make is whether the air leaving the unit is genuinely cold or merely moving.

If the air is cool but weak, the problem is airflow. If the air is not cold at all, the fault sits in the refrigeration circuit or the controls.

Likely causes

01

Blocked filters and a dirty evaporator coil

The most common cause by a wide margin, especially close to the coast where grit and salt film collect quickly. Restricted airflow drops capacity and can freeze the coil.

02

Undersized capacity for the glazing

A unit chosen on floor area will lose against west-facing glass and an uninsulated roof. This is a specification problem, and no repair will fix it.

03

Low refrigerant from a slow leak

Coastal installations corrode at joints and flares. A recharge without finding the leak is a temporary fix that hides a growing problem.

04

Outdoor unit overheating

Units boxed into a courtyard, an enclosed balcony or a shared service recess cannot reject heat. The compressor throttles or cuts out on protection.

05

Sensor or control fault

A faulty room sensor reads the space as colder than it is, so the system satisfies early and the room drifts warm while the display looks normal.

What you can check safely

  • Confirm the mode is cooling and the set point is at least five degrees below room temperature.
  • Rinse the indoor filters if they are visibly dusty.
  • Check that the outdoor unit has clear airflow and is not enclosed.
  • Look for ice on the indoor coil or pipework, which points to airflow or refrigerant.

Please do not open refrigeration circuits, bypass protection devices or work on electrical connections. Those need instrumentation and the right qualifications.

When to book a visit

If the filters are clean, the unit has clear airflow and the room still will not cool, the fault needs instrumentation: pressures, current draw, sensor readings and airflow. Book a diagnostic visit rather than adding gas blindly.

Related questions

Next step

Describe the fault and we will take it from there

Send the details and we will come back with the next step. For anything urgent, call or WhatsApp and describe the fault: we will tell you what to do before we arrive.

What helps: the make of the equipment, what it is doing (or not doing), how long it has been like that, and whether the property is occupied.

Where we work: Milnerton, Century City & Royal Ascot. We do not cover suburbs assigned to other Reyds teams, so the local detail on this site stays accurate.

Milnerton source tag applied to every enquiry

Direct contact

Prefer to speak now?

Monday to Friday, 07:30 to 17:00, and Saturday mornings by arrangement. Emergency refrigeration work is taken by phone and attended as soon as the schedule allows.

Enquiry

Tell us about the property

A short description is enough. We reply with the next step, not a sales call.

Your details are used to respond to this request and are stored on the Milnerton lead pipeline. Details are never sold. See the privacy notice for how enquiries are handled.

CallWhatsAppEnquire